Part Number Hot Search : 
TDA73 3222E MAX3638 JMC261 L88016 G4121208 SP805TCP 1206L
Product Description
Full Text Search
 

To Download B44066T0025E40207 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Thyristor module for dynamic PFC
Accessories for Power Factor Correction
Series/Type: TSM-LC25/TSM-LC50 Ordering code: B44066T0025E402/B44066T0050E402 Date: Version: May 2007 4
Content of inside pages of data sheet. Data will be automatically entered into frontpage headlines, headers and footers. Please fill in the table and then change the colour to "White". This ensures that the table disappears for the customer pdf.
Identification/Classification 1: (header 1) Identification/Classification 2: (header 2) Ordering code: Series/Type: Preliminary data (optional): (if necessary) Department: Date: Thyristor module for dynamic PFC Accessories for Power Factor Correction B44066T0025E402/B44066T0050E402 TSM-LC25/TSM-LC50 Preliminary data FK PC PM PFC May 2007
(c) EPCOS AG 2007. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
Thyristor module for dynamic PFC Accessories for Power Factor Correction
Preliminary data Characteristics
Fast electronically controlled self observing thyristor switch Usage in dynamic (fast) power factor correction systems For capacitive loads up to 50 kvar
B44066T0025E402/B44066T0050E402 TSM-LC25/TSM-LC50
Features
Easy installation: self-check after turn-on of main voltage Display and control via LED-display Permanent self-controlling: voltage parameters, phase sequence, capacitor output, temperature
Technical data
Dimensions Weight Voltage Maximum voltage - in conventional PFC-systems (without reactors) - in detuned PFC-systems (7% detuning) - in detuned PFC-systems (14% detuning) Frequency Max. power 440 V 440 V (no upward tolerance permitted) 400 V 50 Hz/60 Hz TSM-LC 25: 25 kvar for PFC-systems with/without reactors up to 14% TSM-LC 50: 50 kvar for PFC-systems with/without reactors up to 14% (cascading of several modules possible for increasing the kvar output) 10 ... 24 V DC, internally insulated Operation, faults, activation, temperature Note: Before re-switching after temperature fault, heat sink temperature must be below 50 C (hysteresis)! Display Power circuit Thermal power Fuses* (required for protection of TSM-LC and capacitor): *not included in the delivery Switching time Operating ambient temperature Ordering code 2 LEDs/phase connection: 2 x two-phase (L1, L3) with 4 terminals 25 mm2 cross section PD (W) = 2.0 x I (A) 25 kvar: at 400 V typical 75 W 50 kvar: at 400 V typical 150 W 3 x electronic fuse superflink" (NH00 AC 690 V) 50 kvar: 125 A (e.g. SIBA Art.No.: 20 209 20-125) 25 kvar: 63 A (e.g. SIBA Art.No.: 20 209 20-63) approx. 5 ms -10 C ... +55 C TSM-LC 25: B44066T0025E402 TSM-LC 50: B44066T0050E402 157 x 200 x 180 mm (w x h x d) 4.8 kg 3 x 400 V
Activation Monitoring
FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Page 2 of 6
May 2007
Thyristor module for dynamic PFC Accessories for Power Factor Correction
Preliminary data Connection diagram
Three-phase load (standard)
Capacitor branch L1 (R) L2 (S) L3 (T) N PE Fuse superfast 125A at 50kvar 63A at 25 kvar
B44066T0025E402/B44066T0050E402 TSM-LC25/TSM-LC50
input (controller signal)
_ + S ignal 10-24VDC
L1 fault/ "O n" operation
L3 fault/ "O n" operation
TSM - LC
electronic thyristor-module for capacitor switching
C1
L1
L3
C3
FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Page 3 of 6
May 2007
Thyristor module for dynamic PFC Accessories for Power Factor Correction
Preliminary data Connection diagram
Single (two) phase load e.g. single phase welding machine
L1 (R) L2 (S) L3 (T)
B44066T0025E402/B44066T0050E402 TSM-LC25/TSM-LC50
PE
input (controller signal)
+_ S ignal 10-24VDC
L1 fault/ "O n" operation
L3 fault/ "O n" operation
TSM - LC
electronic thyristor-module for capacitor switching
C1
L1
L3
C3
C1
C2
FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Page 4 of 6
May 2007
Thyristor module for dynamic PFC Accessories for Power Factor Correction
Preliminary data Cautions and warnings
B44066T0025E402/B44066T0050E402 TSM-LC25/TSM-LC50
General * Thyristor modules TSM series may only be used for the purpose they have been designed for. * Thyristor modules TSM series may only be used in combination with appropriate pre-switched grid separator device. * Thyristor modules have to be projected in such a way that in case of any failure no uncontrolled high current and voltages may occur. * The devices in operation have to be protected against moisture and dust, sufficient cooling has to be assured. Attention Due to the switching principle of the thyristor module the power capacitors are permanently loaded to the peak value of the grid voltage (DC voltage) even when switched off. Therefore the following rules have to be obeyed in any case: * For standard PFC-systems (without reactors) power capacitors of 440 V nominal voltage have to be used; for detuned systems PFC capacitors of 525 V nominal voltage have to be used. * Due to the high voltage (2 x peak value of nominal voltage) that occurs, the discharge resistors of the power capacitors have to be replaced by special types. * In dynamic systems with TSM modules no fast discharge reactors may be used (reactor = DCwise short circuit). * For standard PFC-systems 2 current limiting reactors are mandatory per thyristor module. * Thyristor modules in general have to be protected by superfast electronic fuses. Principles for dimensioning have to be considered. Fuses in the system have to be marked. * Due to the special switching, the PFC capacitors are fully loaded even when the particular step has been switched off. Protection against contact has to be guaranteed. Warning signals in the systems are required. * Even in switched off state no electrical isolation is achieved for electronic switches. Therefore parts of the systems may not be touched after switching off the complete system before the capacitors have been completely discharged. FAILURE TO FOLLOW CAUTIONS MAY RESULT, WORST CASE, IN PREMATURE FAILURES OR PHYSICAL INJURY.
U Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual
version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications. Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering.
FK PC PM PFC Please read Cautions and warnings and Important notes at the end of this document. Page 5 of 6
May 2007
Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as "hazardous"). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of
the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, MiniBlue, MLSC, MotorCap, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
FK PC PM PFC Page 6 of 6
May 2007


▲Up To Search▲   

 
Price & Availability of B44066T0025E40207

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X